Show simple item record

Estudo da resistência à tração em ancoragens estruturais pós-instaladas com adesivo epóxi;
Estudio de la resistencia a tracción en anclajes estructurales posinstalados con adhesivo epóxico

dc.contributor.authorPáez Moreno, Diego Fernando
dc.contributor.authorHamón Caicedo, Jeniffer
dc.date.accessioned2019-11-07T15:03:03Z
dc.date.available2019-11-07T15:03:03Z
dc.date.created2018-03-04
dc.identifier.issn1692-3324
dc.identifier.urihttp://hdl.handle.net/11407/5517
dc.description.abstractResearch carried out on post-installed structural anchors has shown a link between the embedded length and the diameter of the bore with maximum tensile strength. This paper, is the outcome of research funded by the research department of the Universidad Pedagógica y Tecnológica de Colombia, analyzes this link from the variation of resistance and failure type in structural anchor prototypes with variations in embedded length and drilling diameter, in particular compressive strength 28 MPa, epoxy adhesive, reinforcing bar, 15 graphite units of 0.007 m diameter, and 15 corrugated steel units of 0.0095 m diameter, for a total of 30 systems requested for direct traction in the universal machine. The results showed that tensile strength and failure type are a function of the embedded length and corrugated structure of the anchored reinforcing bar.eng
dc.description.abstractPesquisas realizadas em ancoragens estruturais pós-instaladas evidenciaram um vínculo entre o comprimento de incorporação e o diâmetro de perfuração com a resistência máxima à tração. O presente artigo, resultado de uma pesquisa financiada pela direção de pesquisas da Universidad Pedagógica y Tecnológica de Colombia, analisa esse vínculo a partir da variação da resistência e do tipo de falha em protótipos de ancoragem estrutural com variações no comprimento de incorporação e diâmetro de perfuração em concreto de resistência à compressão 28 MPa, adesivo epóxi, barra de reforço, 15 unidades de arame trefilado de 0,007 m de diâmetro e 15 unidades de aço corrugado de 0,0095 m de diâmetro, para um total de 30 sistemas solicitados à tração direta na máquina universal. Os resultados mostraram que a resistência à tração e ao tipo de falha ocorrem em função do comprimento de incorporação e da estrutura corrugada da barra de reforço ancorada.por
dc.description.abstractInvestigaciones realizadas en anclajes estructurales posinstalados, han evidenciado un vínculo entre la longitud de embebido y el diámetro de perforación con la resistencia máxima a tracción. El presente artículo, resultado de una investigación financiada por la dirección de investigaciones de la Universidad Pedagógica y Tecnológica de Colombia, analiza este vínculo a partir de la variación de la resistencia y el tipo de falla en prototipos de anclaje estructural con variaciones en la longitud de embebido y diámetro de perforación, en concreto de resistencia a la compresión 28 MPa, adhesivo epóxico, barra de refuerzo, 15 unidades de grafil de diámetro 0,007 m, y 15 unidades de acero corrugado de diámetro 0,0095 m, para un total de 30 sistemas solicitados a tracción directa en la máquina universal. Los resultados mostraron que la resistencia a tracción y el tipo de falla están en función de la longitud de embebido y la estructura corrugada de la barra de refuerzo anclada.spa
dc.format.extentp. 57-70spa
dc.format.mediumElectrónicospa
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad de Medellínspa
dc.relation.urihttps://revistas.udem.edu.co/index.php/ingenierias/article/view/1789
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceRevista Ingenierías Universidad de Medellín; Vol. 17 Núm. 33 (2018): Julio-Diciembre; 57-70spa
dc.subjectEpoxyresin; Adhesive anchors; Strengtheng
dc.subjectResina epóxi; Ancoragens adesivas; Resistênciapor
dc.subjectResina epóxica; Anclajes adhesivos; Resistenciaspa
dc.titleStudy of Tensile Strength in Structural Anchors Post-Installed with Epoxy Adhesiveeng
dc.titleEstudo da resistência à tração em ancoragens estruturais pós-instaladas com adesivo epóxipor
dc.titleEstudio de la resistencia a tracción en anclajes estructurales posinstalados con adhesivo epóxicospa
dc.typeArticleeng
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.identifier.doihttps://doi.org/10.22395/rium.v17n33a3
dc.relation.citationvolume17
dc.relation.citationissue33
dc.relation.citationstartpage97
dc.relation.citationendpage70
dc.audienceComunidad Universidad de Medellínspa
dc.publisher.facultyFacultad de Ingenieríasspa
dc.coverageLat: 06 15 00 N  degrees minutes  Lat: 6.2500  decimal degreesLong: 075 36 00 W  degrees minutes  Long: -75.6000  decimal degrees
dc.publisher.placeMedellínspa
dc.creator.affiliationPáez Moreno, Diego Fernando; Universidad Pedagógica y Tecnológica de Colombiaspa
dc.creator.affiliationHamón Caicedo, Jeniffer; Universidad Pedagógica y Tecnológica de Colombiaspa
dc.relation.references[1] República de Colombia. Ministerio de Ambiente, Vivienda y Desarrollo Territorial, Reglamento Colombiano de Construcción Sismo Resistente Nsr-10, Asociación Colombiana de Ingeniería Sísmica, 2010.spa
dc.relation.references[2] J. Rendón, “Los anclajes adhesivos en la construcción”, Noticreto, vol. 126, pp. 43-47, 2014.spa
dc.relation.references[3] Committee ACI 503, Use of epoxy compounds with concrete, ACI 503 R-93, American Concrete Institute, 1998.spa
dc.relation.references[4] M. Gesoğlu et al., “Modeling and analysis of the shear capacity of adhesive anchors postinstalled into uncracked concrete,” Composites: Part B: Engineering, vol. 60, pp. 716-724, 2014.spa
dc.relation.references[5] M. Obataa et al., “The failure mechanism and the pull-out strength of a bond-type anchor near a free edge,” Mechanics of Materiales, vol. 28, pp. 113-122, 1998.spa
dc.relation.references6] P. Upadhyaya, y S. Kumar, “Pull-out capacity of adhesive anchors: An analytical solution,” International Journal of Adhesion and Adhesives, vol. 60, pp.54-62, 2015.spa
dc.relation.references[7] Ϛ. Ózlem et al., “Shear strength of epoxy anchors embedded into low strength concrete,” Construction and Building Materials, vol. 38, pp. 723-730, 2012.spa
dc.relation.references[8] S. Yang et al., “Theoretical analysis on pullout of anchor from anchor–mortar–concrete anchorage system,” Engineering Fracture Mechanics, vol. 75, pp. 961-985, 2008.spa
dc.relation.references[9] A. Çolak, “Parametric study of factors affecting the pull-out strength of steel rods bonded into precast concrete panels,” International Journal of Adhesion and Adhesives, vol. 21, pp. 487-493, 2001.spa
dc.relation.references[10] Y. M. Ruda Arias y D.F. Páez Moreno “Anclajes posinstalados en concreto de alta resistencia,” Ciencia e Ingeniería Neogranadina, vol. 27, N.° 2, pp. 137-156, 2017.spa
dc.relation.references[11] M. McVay, et al., “Pullout simulation of post installed chemically bonded anchors,” Journal Structural Engineering, Vol.122, pp. 1016-1024, 1996.spa
dc.relation.references[12] L. Contrafatto, y R. Cosenza, “Behavior of post-installed adhesive anchors in natural stone,” Construction and Building Materiales, vol. 68, pp. 355-369, 2014.spa
dc.relation.references[13] F. Puigvert et al., “Static analysis of adhesively bonded anchorages for CFRP tendons,” Construction and Building Material, vol. 61, pp. 206-215, 2014.spa
dc.relation.references[14] B. Gerber and M. Ekenel, “Building Code Requirements for Inspection of Adhesive Anchors in Concrete”, Journal of Construction Enigneering and Management, vol. 139, 2013.spa
dc.relation.references[15] Post-Installed Reinforcing Bar Guide, Hilti Group, 2016.spa
dc.relation.references[16] Committee ACI 318-11, Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute, 2011.spa
dc.relation.references[17] Sika Colombia S.A., “Hoja técnica Sikadur AnchorFix-4,” [En línea], acceso 14 de abril, 2015; Disponible: http://col.sika.com/es/rehabilitacion-y-reforzamiento/rehabilitarreforzar/02a005/02a005sa01.htmlspa
dc.relation.references[18] M. Lascarro, “Indicadores en concreto,” [En línea], acceso 14 de abril, 2015; Disponible: https://www.construccionlatinoamericana.com/indicadores-en-concreto/128416.articlespa
dc.relation.references[19] Icontec, Concretos. Ensayo resistencia a la compresión de especímenes cilíndricos de concreto, NTC 673, Instituto Colombiano de Normas Técnicas y Certificación Icontec, 2012.spa
dc.relation.references[20] Icontec, Siderurgia. Ensayo de tracción para materiales metálicos. Método de ensayo a temperatura ambiente, NTC 2, I nstituto Colombiano de Normas Técnicas y Certificación Icontec, 1995.spa
dc.relation.references[21] ASTM International, ASTM E488/488M–10 Standard Test Methods for Strength of Anchors in Concrete Elements, ASTM INTERNATIONAL, 2014.spa
dc.relation.references[22] Committee ACI 355, Report on Anchorage to Concrete, ACI 355 1R-91 (Reapproved 1997), American Concrete Institute, 1997.spa
dc.rights.creativecommonsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.identifier.eissn2248-4094
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.type.localArtículo científicospa
dc.type.driverinfo:eu-repo/semantics/article
dc.identifier.reponamereponame:Repositorio Institucional Universidad de Medellínspa
dc.identifier.repourlrepourl:https://repository.udem.edu.co/
dc.identifier.instnameinstname:Universidad de Medellínspa
dc.relation.ispartofjournalRevista Ingenierías Universidad de Medellínspa


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International