REPOSITORIO
INSTITUCIONAL

    • español
    • English
  • Site map
  • English 
    • español
    • English
  • Login
  • Artículos(current)
  • Libros
  • Tesis
  • Trabajos de grado
  • Documentos Institucionales
    • Actas
    • Acuerdos
    • Decretos
    • Resoluciones
  • Multimedia
  • Productos de investigación
  • Acerca de
View Item 
  •   Home
  • Artículos
  • Indexados Scopus
  • View Item
  •   Home
  • Artículos
  • Indexados Scopus
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effective phosphorus removal using transformed water hyacinth: Performance evaluation in fixed-bed columns and practical applications

Thumbnail
Share this
Date
2024
Author
Ramirez-Muñoz A.; Flórez E.; Ocampo-Perez R.; Acelas N.

Citación

       
TY - GEN T1 - Effective phosphorus removal using transformed water hyacinth: Performance evaluation in fixed-bed columns and practical applications Y1 - 2024 UR - http://hdl.handle.net/11407/8834 AB - This study introduces calcined water hyacinth (CWH), processed at 650◦C, as a novel and environmentally friendly adsorbent for phosphorus (P) removal from wastewater. Building on previous findings that identified CWH as a rich source of metal oxides and hydroxides (e.g., Ca(OH)2, Al2O3, MgO, Fe3O4), this research explores its application in fixed-bed column systems for continuous adsorption processes. The study demonstrates that CWH effectively removes phosphorus through apatite formation, showcasing its potential for real-world water treatment. The phosphorus adsorption capacity increased from 23.64 to 26.55 mg/g when the flow rate was reduced from 1.5 to 0.5 mL/min. Breakthrough curves fitted to the Thomas, Adams-Bohart, and Yoon-Nelson models provided critical insights into column performance, while the Bed Depth Service Time (BDST) model confirmed the feasibility of employing CWH in continuous-flow systems. The practical tests on synthetic municipal wastewater, which revealed a maximum adsorption capacity of 5.20 mg/g, further demonstrated CWH’s effectiveness for treating wastewater with low phosphorus concentrations, providing reassurance about its real-world applicability. Furthermore, the study found that increasing the adsorbent height improved column performance by extending breakthrough and exhaustion times, whereas higher flow rates led to faster saturation and reduced capacity. The exhausted CWH material can be repurposed as a soil amendment or fertilizer feedstock, supporting nutrient recycling. Copyright: © 2024 Ramirez-Muñoz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. ER - @misc{11407_8834, author = {}, title = {Effective phosphorus removal using transformed water hyacinth: Performance evaluation in fixed-bed columns and practical applications}, year = {2024}, abstract = {This study introduces calcined water hyacinth (CWH), processed at 650◦C, as a novel and environmentally friendly adsorbent for phosphorus (P) removal from wastewater. Building on previous findings that identified CWH as a rich source of metal oxides and hydroxides (e.g., Ca(OH)2, Al2O3, MgO, Fe3O4), this research explores its application in fixed-bed column systems for continuous adsorption processes. The study demonstrates that CWH effectively removes phosphorus through apatite formation, showcasing its potential for real-world water treatment. The phosphorus adsorption capacity increased from 23.64 to 26.55 mg/g when the flow rate was reduced from 1.5 to 0.5 mL/min. Breakthrough curves fitted to the Thomas, Adams-Bohart, and Yoon-Nelson models provided critical insights into column performance, while the Bed Depth Service Time (BDST) model confirmed the feasibility of employing CWH in continuous-flow systems. The practical tests on synthetic municipal wastewater, which revealed a maximum adsorption capacity of 5.20 mg/g, further demonstrated CWH’s effectiveness for treating wastewater with low phosphorus concentrations, providing reassurance about its real-world applicability. Furthermore, the study found that increasing the adsorbent height improved column performance by extending breakthrough and exhaustion times, whereas higher flow rates led to faster saturation and reduced capacity. The exhausted CWH material can be repurposed as a soil amendment or fertilizer feedstock, supporting nutrient recycling. Copyright: © 2024 Ramirez-Muñoz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.}, url = {http://hdl.handle.net/11407/8834} }RT Generic T1 Effective phosphorus removal using transformed water hyacinth: Performance evaluation in fixed-bed columns and practical applications YR 2024 LK http://hdl.handle.net/11407/8834 AB This study introduces calcined water hyacinth (CWH), processed at 650◦C, as a novel and environmentally friendly adsorbent for phosphorus (P) removal from wastewater. Building on previous findings that identified CWH as a rich source of metal oxides and hydroxides (e.g., Ca(OH)2, Al2O3, MgO, Fe3O4), this research explores its application in fixed-bed column systems for continuous adsorption processes. The study demonstrates that CWH effectively removes phosphorus through apatite formation, showcasing its potential for real-world water treatment. The phosphorus adsorption capacity increased from 23.64 to 26.55 mg/g when the flow rate was reduced from 1.5 to 0.5 mL/min. Breakthrough curves fitted to the Thomas, Adams-Bohart, and Yoon-Nelson models provided critical insights into column performance, while the Bed Depth Service Time (BDST) model confirmed the feasibility of employing CWH in continuous-flow systems. The practical tests on synthetic municipal wastewater, which revealed a maximum adsorption capacity of 5.20 mg/g, further demonstrated CWH’s effectiveness for treating wastewater with low phosphorus concentrations, providing reassurance about its real-world applicability. Furthermore, the study found that increasing the adsorbent height improved column performance by extending breakthrough and exhaustion times, whereas higher flow rates led to faster saturation and reduced capacity. The exhausted CWH material can be repurposed as a soil amendment or fertilizer feedstock, supporting nutrient recycling. Copyright: © 2024 Ramirez-Muñoz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. OL Spanish (121)
Gestores bibliográficos
Refworks
Zotero
BibTeX
CiteULike
Metadata
Show full item record
Abstract
This study introduces calcined water hyacinth (CWH), processed at 650◦C, as a novel and environmentally friendly adsorbent for phosphorus (P) removal from wastewater. Building on previous findings that identified CWH as a rich source of metal oxides and hydroxides (e.g., Ca(OH)2, Al2O3, MgO, Fe3O4), this research explores its application in fixed-bed column systems for continuous adsorption processes. The study demonstrates that CWH effectively removes phosphorus through apatite formation, showcasing its potential for real-world water treatment. The phosphorus adsorption capacity increased from 23.64 to 26.55 mg/g when the flow rate was reduced from 1.5 to 0.5 mL/min. Breakthrough curves fitted to the Thomas, Adams-Bohart, and Yoon-Nelson models provided critical insights into column performance, while the Bed Depth Service Time (BDST) model confirmed the feasibility of employing CWH in continuous-flow systems. The practical tests on synthetic municipal wastewater, which revealed a maximum adsorption capacity of 5.20 mg/g, further demonstrated CWH’s effectiveness for treating wastewater with low phosphorus concentrations, providing reassurance about its real-world applicability. Furthermore, the study found that increasing the adsorbent height improved column performance by extending breakthrough and exhaustion times, whereas higher flow rates led to faster saturation and reduced capacity. The exhausted CWH material can be repurposed as a soil amendment or fertilizer feedstock, supporting nutrient recycling. Copyright: © 2024 Ramirez-Muñoz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
URI
http://hdl.handle.net/11407/8834
Collections
  • Indexados Scopus [2099]

Related items

Showing items related by title, author, creator and subject.

  • Thumbnail

    Probabilistic Cascade Modeling for Enhanced Flood and Landslide Hazard Assessment: Integrating Multi-Model Approaches in the La Liboriana River Basin 

    Vega J.; Ortiz-Giraldo L.; Botero B.A.; Hidalgo C.; Parra J.C. (Ingeniería CivilFacultad de Ingenierías, 2024)
    Extreme rainfall events in Andean basins frequently trigger landslides, obstructing river channels and causing flash flows, loss of lives, and economic damage. This study focused on improving the modeling of these events ...
  • Thumbnail

    Propuesta de integración del modelo para construcción de soluciones y el modelo de negocio Canvas para el desarrollo de sistemas telemáticos 

    Burbano Santacruz, Diego Fernando; Rojas Pineda, Eduardo (Universidad de MedellínFacultad de IngenieríasMedellín, 2017-12-31)
  • Thumbnail

    Simulating current-energy converters: SNL-EFDC model development, verification, and parameter estimation 

    James S.C.; Johnson E.L.; Barco J.; Roberts J.D.
    Increasing interest in power production from ocean, tidal, and river currents has led to significant efforts to maximize energy conversion through optimal design and siting and to minimize effects on the environment. ...
All of RI UdeMCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects
My AccountLoginRegister
Statistics GTMView statistics GTM
OFERTA ACADÉMICA
  • Oferta académica completa
  • Facultad de Derecho
  • Facultad de Comunicación
  • Facultad de Ingenierías
  • Facultad de Ciencias Económicas y Administrativas
  • Facultad de Ciencias Sociales y Humanas
  • Facultad de Ciencias Básicas
  • Facultad de Diseño
SERVICIOS
  • Teatro
  • Educación continuada
  • Centro de Idiomas
  • Consultorio Jurídico
  • Centro de Asesorías y Consultorías
  • Prácticas empresariales
  • Operadora Profesional de Certámenes
INVESTIGACIÓN
  • Biblioteca
  • Centros de investigación
  • Revistas científicas
  • Repositorio institucional
  • Universidad - Empresa - Estado - Sociedad

Universidad de Medellín - Teléfono: +57 (4) 590 4500 Ext. 11422 - Dirección: Carrera 87 N° 30 - 65 Medellín - Colombia - Suramérica
© Copyright 2012 ® Todos los Derechos Reservados
Contacto

 infotegra.com