dc.description | Acceder a agua de buena calidad en las comunidades rurales de los países en vías de desarrollo es en la actualidad un reto; el uso de mantas sintéticas en los sistemas de filtración lenta para la potabilización puede convertirse en una opción eficiente en sistemas de abastecimiento rurales de mediana y pequeña envergadura, fundamentada en el uso de materiales alternativos, que en la actualidad se han estudiado muy poco si los comparamos con la filtración lenta en arena convencional. En el presente trabajo se evaluó la eficiencia de remoción de contaminantes para el tratamiento del agua por medio de una manta sintética no tejida usada en un sistema de filtración lenta. Para esto se evaluaron tres configuraciones de filtros lentos con y sin manta sintética como medio filtrante y se evaluó la remoción de turbiedad, color aparente, materia orgánica y Escherichia coli (E.coli) con tasas de filtración de 6, 9 y 12 m3/m2.día.También se realizó un seguimiento a la capa biológica que se estableció en cada uno de los sistemas de filtración. Se encontró que el sistema de filtración que mejor se comporta es el que posee manta sintética superficialmente a una tasa de filtración de 6 m3/m2.día, alcanzando remociones para turbiedad de 98%, color aparente del 91%, materia orgánica del 72% y de E. coli del 99% (3,1Log). | spa |
dc.description.abstract | Access to good quality water in rural communities of developing countries is a challenge; the use of synthetic Fabrics in slow filtration systems for potabilization can be an effective option in medium and small scale rural water supply systems, based on the use of alternative materials that have been studied very little if compared with conventional slow sand filtration. Non-woven synthetic fabric in a slow filtration system to water treatment was evaluated. For this we evaluated three different configurations of slow filters with and without non-woven synthetic fabric as a filter medium and determining the removal of turbidity, apparent color, organic matter and Escherichia coli (E. coli) using flows of 6, 9 and 12m3/m2.day. Additionally, the development of the established biofilm in each of the filtration systems. The system composed by sand and synthetic fabric on the surface using a flow of 6 m3/m2.day showed the highest efficiency, reaching removing of 98% for turbidity, 91% of apparent color, 72% of organic matter (TOC), and 99% of E. coli (3,2Log). | eng |
dc.format.mimetype | application/pdf | |
dc.publisher | Universidad de Medellín | spa |
dc.subject | Filtración lenta | spa |
dc.subject | Mantas sintéticas no tejidas | spa |
dc.subject | Tratamiento de agua | spa |
dc.subject | Agua potable | spa |
dc.subject | Ingeniería urbana | spa |
dc.subject | Calidad del agua - Control | spa |
dc.subject | Calidad del agua - Mediciones | spa |
dc.subject | Filtros y filtración | spa |
dc.title | Evaluación de una manta sintética no tejida en un sistema piloto de filtración lenta para el tratamiento del agua | spa |